Product Description
~Timer Relay Module DRM*2 User
Menu
The multifunction relay control module (DRM*2), designed for the
customers different needs, micro-controller as the main control
unit, preset *0 kinds of function, also can be based on users need,
customize and add other specific function.The module using of high
quality power relay module, highpower and high voltagetransistor,
red & blue signal lights, double sided PCB board, stable
performance,can be widely used in a variety of power control
occasions.
Product features
1.***5 new upgrade version,increased the collaboration function for
each channel;
2.With 2 ways and output control,each channel can be set to
*0 kinds of functions,could meet the needs of more applications
3.DC 8V- *6V wide voltage ,increased the power anti reverse
function,the module cant be damaged because of a wrong power
supply
4.With a red power indicator light,a blue relay indicator light
;
5.The minimum timing can be set to 0.1 seconds,timing accuracy
better than 0.*1 seconds;
6.Increased automatic power saving function,users can be set by
their own;
7.All settings could automatically save.
8.The trigger signal terminal users can select either high or
low pulse trigger;
~ Module Function
The user can select one of the following *0 kinds of function
according to keys and display tube, can set and save the
parameters, time parameter sets the minimum 0.1 second adjustable,
more expertise.
[Function 1]
Timing Pull-in:after power on, when arrived the setting time
[T1],the relay pull-in,
and the [T1] can be adjustable between 0.1 second ***0 hours, give
[X] interface a high pulse signal(high level duration≥*0ms),repeat
the above function.
[Function 2]
Timing Disconnect:after power on the relay pull-in, when arrived
the setting time
[T1],the relay disconnect, and the [T1]can be adjustable between
0.1 second ***0 hours,give [X] interface a high pulse signal(high
level duration≥*0ms),repeat the above function.
[Function 3]
Timing Pull-in Then Disconnect: after power on, the relay dont
pull-in, when
arrived the setting time [T1] relay pull-in; when arrived the
setting time [T2 ]relay
disconnect,and the [T1] and [T2] can be adjustable between 0.1
second ***0 hours, give[X]interface a high pulse signal(high level
duration≥*0ms),repeat the above
function.
[Function 4]
Timing Disconnect Then Pull-in : after power on, the relay
immediately pull-in, when
arrived the setting time [T1] relay disconnect; when arrived the
setting time [T2]relay pull-in, and the [T1] and [T2] can be
adjustable between 0.1 second ***0 hours, give[X] interface a high
pulse signal(high level duration≥*0ms),repeat the above
function.
[Function 5]
Unlimited Cycle Mode A: after power on, the relay dont pull-in,
when arrived
the setting time [T1] relay pull-in; when arrived the setting time
[T2] relay disconnect,then repeat the above status, and the [T1]
and [T2] can be adjustable between 0.1 second***0 hours, give [X]
interface a high pulse signal(high level duration≥*0ms),repeat the
above function.
[Function 6]
Unlimited Cycle Mode B: after power on, the relay immediately
pull-in, when arrived the setting time [T1]relay disconnect; when
arrived the setting time [T2] relay pull-in,then repeat the above
status, and the [T1] and [T2] can be adjustable between 0.1 second
***0 hours, give [X] interface a high pulse signal(high level
duration≥*0ms),repeat the above function.
[Function 7]
Limited Cycle Mode A: after power on, the relay dont pull-in, when
arrived
the setting time [T1] relay pull-in; when arrived the setting time
[T2] relay disconnect,then repeat the above status "NX" times, the
[T1] and [T2] can be adjustable between 0.1 second ****9 seconds,
the cycle times "NX" can be adjustable between *****9,give[X]
interface a high pulse signal(high level duration≥*0ms),repeat the
above function.
[Function 8]
Limited Cycle Mode B: after power on, the relay immediately
pull-in, when
arrived the setting time [T1] relay disconnect; when arrived the
setting time [T2] relay pull-in,then repeat the above status "NX"
times, the [T1] and [T2] can be adjustable between 0.1 second ****9
seconds, the cycle times "NX" can be adjustable between *****9,
give [X] interface a high pulse signal(high level
duration≥*0ms),repeat the above function.
[Function 9]
Self-locking Mode:give [X] interface a high pulse signal, the relay
pull-in, again
give a high pulse signal, the relay disconnect.
[Function *0]
Trigger Mode:contain delay off function, the relay does not operate
after power
on ,give [X] interface a high pulse signal, the relay pull-in
immediately, when
the high pulse signal disappeared, the relay still pull-in, when
arrived the setting
time [T1] relay disconnect, the [T1] can be adjustable between 0
second***0 hours.
Remarks: in this function, if[ T1] is 0 second, give [X] interface
a high pulse signal,the relay pull-in, when the high pulse signal
disappeared, the relay immediately disconnect.
[Function *1]
Trigger mode A :the relay does not operate after power on ,give [X]
interface
a high pulse signal, when arrived the timing time [T1],the relay
pull-in ,T1 can be adjustable between 0.1 second ***0 hours, give
[X] interface a high pulse signal
again, repeat the above function one time.
[Function *2]
Trigger mode B:the relay does not operate after power on ,give [X]
interface
a high pulse signal, the relay pull-in , when arrived the timing
time [T1], the relay
disconnect,[T1] can be adjustable between 0.1 second ***0 hours,
give [X] interface a high pulse signal again, repeat the above
function one time.
[Function *3]
Trigger mode C :the relay does not operate after power on ,give [X]
interface
a high pulse signal, when arrived the timing time [T1],the relay
pull-in ,when arrived the timing time T2,the relay disconnect, [T1]
and [T2] can be adjustable between 0.1 second ***0 hours, give [X]
interface a high pulse signal again, repeat the above function one
time.
[Function *4]
Trigger timing mode D:the relay does not operate after power on
,give [X ]interface
a high pulse signal, the relay pull-in immediately , when arrived
the timing time
[T1], the relay disconnect, when arrived the timing time [T2],the
relay pull-in, [T1] and [T2] can be adjustable between 0.1 second
***0 hours, give [X] interface
a high pulse signal again, repeat the above function one time.
[Function *5]
Unlimited Cycle Mode A:the relay does not operate after power on
,give [X]
interface a high pulse signal, when arrived the timing time
[T1],the relay pull-in ,
when arrived the timing time [T2],the relay disconnect, then repeat
the above status,
[T1]and [T2] can be adjustable between 0.1 second ***0 hours, give
[X] interface a high pulse signal again ,repeat the above
function.
[Function *6]
Unlimited Cycle Mode B:the relay does not operate after power on
,give [X]
Interface a high pulse signal, the relay pull-in immediately, when
arrived the timing
time[T1],the relay disconnect, when arrived the timing time
[T2],the relay pull-in,then repeat the above status , [T1]and [T2]
can be adjustable between 0.1 second ***0 hours,give [X] interface
a high pulse signal again ,repeat the above function.
[Function *7]
Limited Cycle Mode A:the relay does not operate after power on
,give [X]interface a high pulse signal, when arrived the timing
time [T1],the relay pull-in ,when arrived the timing time [T2],the
relay disconnect, then repeat the above status
"NX" times, [T1] and [T2] can be adjustable between 0.1 second
****9 seconds, the
cycle times "NX" can be adjustable between *****9,give [X]interface
a high pulse
signal again ,repeat the above function.
[Function *8]
Limited Cycle Mode B:the relay does not operate after power on ,
give [X]
Interface a high pulse signal, the relay pull-in immediately, when
arrived the timing
time [T1],the relay disconnect, when arrived the timing time
[T2],the relay pull-in,
then repeat the above status "NX" times, [T1] and [T2]can be
adjustable between
0.1 second ****9 seconds, the cycle times "NX" can be adjustable
between *****9,give
[X]connector a high pulse signal again ,repeat the above
function.
[Function *9]
Condition Cycle Mode A:the relay does not operate after power on ,
give [X]
connector a high pulse signal,when arrived the timing time [T1],the
relay pull-in immediately,when arrived the timing time [T2]the
relay disconnect,as long as[X] connector high pulse signal not
disappear ,the module will repeat the above function, [T1] and
[T2]can be adjustable between 0.1 second ***0 hours,if [X]
interface high pulse signal disappear,the relay will disconnect
immediately.
[Function *0]
Condition Cycle Mode B:the relay does not operate after power on ,
give [X]connector a high pulse signal,the relay pull-in
immediately,when arrived the timing time [T1],the relay
disconnect;when arrived the timing time [T2],the relay pull -in. As
long as[X] interface high pulse signal not disappear ,the module
will repeat the above function, [T1] and [T2]can be adjustable
between 0.1 second ***0 hours,if [X] interface high pulse signal
disappear,the relay will disconnect immediately.
Electrical parameters
1. Operating Voltage:DC 8V**6V(Limit working voltage DC
6V**8V).
2. Rated power: static power less than 0.1W,turn off the display is
less than 0.*3W
Maximum power is less than 0.9W.
3. Working Temperature:**0—*0(Limit range**0—*0)
4. Load Capacity:
the module normally open interface maximum load
capacity: DC ***0V/*0A,AC
****0V/*0A
the module normally closed interface maximum load
capacity: DC ***8V/*0A,AC
****5V/*0A
Restrictions:
1. relay life is loaded with action **0,**0 times, and therefore
more suitable for
use in low frequency and high current pull control of the
situation, is not suitable
for repeated use in the fast-action situations;.
2. Note consider relay port load margin, purely resistive load more
than doubled
to left margin, ordinary inductive or capacitive loads must be at
least three times
more margin.
Module Interface
Module Voltage/Signal Inpu:There have 5 connectors, all connectors
have terminal, user easy to use.
1.DC+:DC power positive;
2.DC:DC power negative;
3.XM:Optically isolated s common interface;
4.X1:Input signal interface 1;
5.X2:Input signal interface 2.
Module Output:There have 6 connectors, all connectors have
terminal.
1.NO1 :Channel 1 normally open interface,the relay becomes vacant
before, after pull-in short with the COM1;
2.COM1:Channel 1 common interface;
3.NC1:Channel 1 normally closed interface, short with COM1 before,
become vacant after pull-in.
4.NO2 :Channel 2 normally open interface,the relay becomes vacant
before, after pull-in short with the COM2;
5.COM2:Channel 2 common interface;
6.NC2 :Channel 2 normally closed interface, short with COM2 before,
become vacant after pull-in.
Dimensions: *5mm * *8mm * *0mm (L * W * H)
Country: |
China |
Model No: |
DRM02A
|
FOB Price: |
13.25 ~ 12.58 / Piece ( Negotiable ) (Negotiable)
Get Latest Price
|
Place of Origin: |
- |
Price for Minimum Order: |
13.25 per Piece |
Minimum Order Quantity: |
1 Piece |
Packaging Detail: |
box |
Delivery Time: |
3days |
Supplying Ability: |
100000 Piece per Month |
Payment Type: |
Western Union, T/T |
Product Group : |
Relay module series
|